APC Power Saving Back-UPS RS 1500 230V CEE 7/5 BR1500G-FR

AC outlet types Type E / F
Battery recharge time 8 h
Battery technology Sealed Lead Acid (VRLA)
Battery type APCRBC124
Cable length 1.83 m
Depth 380 mm

About this item

Specific features:Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Audible alarms: Provide notification of changing flywheel conditionsBattery failure notification: Provides...

View full product description

Product information

About this product

Specific features:

Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Audible alarms: Provide notification of changing flywheel conditions

Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Power-saving outlets: Automatically cuts power to idle equipment to conserve electricity.

LCD display: Alpha-Numeric Display which displays system parameters and alarms.

Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment

Cold-start capable: Provides temporary battery power when the utility power is out.

Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Audible alarms: Provides notification of changing utility power and UPS conditions.

User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

USB connectivity: Provides management of the UPS via a USB port (not available on all models).

Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.

Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery

Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery.

Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.

Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit.

Adjustable voltage sensitivity: Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.

Automatic Voltage Regulation (AVR): Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.

Battery fault detection: Monitors room and individual battery temperature changes for early detection of thermal runaway, shorted cells, open circuit, and bad battery.

Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment.

Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.

Audible alarms: Provides notification of changing utility power and UPS conditions.

Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.

Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery replacement without tools: Allows quick, easy battery replacement.

LED status indicators: Quickly understand unit and power status with visual indicators.

Cold-start capable: Provides temporary battery power when the utility power is out.

Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Resettable circuit breakers: Enables a quick recovery from overload events.

Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.

User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Intelligent battery management: Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.

Product details

34
AC outlet types Type E / F
Battery recharge time 8 h
Battery technology Sealed Lead Acid (VRLA)
Battery type APCRBC124
Cable length 1.83 m
Depth 380 mm
Ethernet LAN (RJ-45) ports 1
Filtering description UL 1449
Harmonized System (HS) code 85078000
Height 301 mm
Input connection type IEC-320 C14
Interface USB
Management card included No
Modem (RJ-11) ports 1
Nominal input voltage 230 V
Nominal output voltage 230 V
Non-operating altitude 0 - 15000 m
Operating altitude 0 - 9000 m
Operating relative humidity (H-H) 0 - 95%
Operating temperature (T-T) 0 - 40 °C, 32 - 104 °F
Output power 865 W
Output power capacity 1.5 kVA
Package dimensions (WxDxH) 238 x 488 x 387 mm
Package weight 13.2 kg
Product colour Black
Replacement battery cartridge 1
SmartConnect port No
SmartSlot No
Storage relative humidity (H-H) 0 - 95%
Storage temperature (T-T) -15 - 45 °C
Surge energy rating 445 J
UPS topology Line-Interactive
Weight 11.6 kg
Width 112 mm

Logistics

EAN0731304268734
Unit of measure—
Weight—
Dimensions —
Dangerous goodsNo

Warranty

  • 12-month warranty on everything we sell.
  • Runs from the day your order is delivered.
  • Faults under normal use are repaired, replaced or refunded.
Read the warranty terms

Payment

  • Clearpay
  • Klarna
  • Visa and Mastercard, processed securely by Tyl by NatWest with 3D Secure.
  • PayPal — your PayPal balance or a saved card or bank account.
  • Clearpay, Klarna and Billie — pay later or in instalments, processed by Stripe.
  • No surcharge on any payment method; refunds go back to the way you paid.
Read the payment policy
Spread the cost
  • Clearpay
  • Klarna
    • Clearpay
    4 interest-free payments of £102.51 with Clearpay. Learn more
    • Klarna
    3 payments of £136.68 at 0% interest with Klarna. Learn more
    Businesses: pay in 30 days on invoice with Billie. Learn more

Choose at checkout. 18+, T&Cs apply, credit subject to status.

Return policy: Item can be returned in its original condition for a full refund within 14 days of receipt, with a free tracked Royal Mail return label. Read full return policy

Recently viewed