Roll over image to zoom in · Click to see full view
Product information
From the manufacturer
About this product
- Dual 1G Ethernet ports support cascading up to 64 PDUs
- Environment sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 ATEN EA1640 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats (sold separately)
- Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking
- With an ARM Cortex-A8 processor, these PDUs provide advanced control options through USB, COM, environmental sensors, and dual Gigabit LAN ports
When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 1U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG8308 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 8 port outlets that can power up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG8308 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 35.04 kw equivalent of power consumption of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.
Real-time Alerts via LCD Display
Once connected to an AC power source, the Home screen displays basic PDU readings, including A (Aggregate Current), V (Voltage), W (Power), and kWh (Power Consumption).
The LCD screen lights up red when a Critical, Alert (triggered when a PDU value exceeds a predefined threshold), or Warning (when a value approaches the alert threshold) event is logged.
Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors (i.e. EA1640, sold separately) for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.
Communicate through RS-232 Protocol
For quick and flexible operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands.
Networkable via WiFi
The PG8308 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.
Dual LAN Ports for Scalable Network Setup
The PG8308 is equipped with dual LAN ports (Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.
DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.
Applications
The PG series intelligent PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in server rooms or data centers.
Product details
27
| AC input frequency | 50-60 Hz |
|---|---|
| AC outlets quantity | 8 AC outlet(s) |
| AC outlet types | C13 coupler, C19 coupler |
| Cable length | 3 m |
| Certification | CE, UKCA |
| Country of origin | Taiwan |
| Depth | 432.4 mm |
| Display | LCD |
| Ethernet LAN (RJ-45) ports | 2 |
| Height | 44 mm |
| LED indicators | Yes |
| Load capacity | 7680 VA |
| Maximum current | 32 A |
| Monitoring | Current, Voltage |
| Nominal input voltage | 100 - 240 V |
| Operating relative humidity (H-H) | 0 - 80% |
| Operating temperature (T-T) | 0 - 60 °C |
| Output voltage | 100 - 240 V |
| PDU types | Metered, Switched |
| Power plug | IEC 60309 |
| Product colour | Black |
| Rack capacity | 1U |
| Reset button | Yes |
| Storage temperature (T-T) | -20 - 60 °C |
| USB ports quantity | 1 |
| Weight | 4.07 kg |
| Width | 210 mm |
Logistics
| EAN | 4710469345739 |
|---|---|
| Unit of measure | — |
| Weight | — |
| Dimensions | — |
| Dangerous goods | No |
Warranty
- 12-month warranty on everything we sell.
- Runs from the day your order is delivered.
- Faults under normal use are repaired, replaced or refunded.
Payment
- Visa and Mastercard, processed securely by Tyl by NatWest with 3D Secure.
- PayPal — your PayPal balance or a saved card or bank account.
- Clearpay, Klarna and Billie — pay later or in instalments, processed by Stripe.
- No surcharge on any payment method; refunds go back to the way you paid.
Spread the cost
- 4 interest-free payments of £217.05 with Clearpay. Learn more
- 3 payments of £289.40 at 0% interest with Klarna. Learn more
- Businesses: pay in 30 days on invoice with Billie. Learn more
Choose at checkout. 18+, T&Cs apply, credit subject to status.